CD-45 2 Rotator - 8.5 sq. ft. Wind Load,
110V

The CD-45II handles 8.5 sq. feet mounted inside a tower, or 5 sq. ft. with
mast adapter.
 | Low temperature grease good to -30 F degrees. |
 | Bell rotator design gives total weather protection, |
 | dual 24 ball bearing races gives proven support. |
 |
Die cast ring gear, |
 |
stamped steel gear drive, |
 |
heavy duty, trouble free gear train. |
 |
North center scale, |
 |
dual lighted directional meter indicator, |
 |
8-pin plug/socket on control unit, |
 |
MSLD light duty lower mast support adapter included. |
Snap-action control switches. Low voltage control. Safe operation, takes
masts to 2 1/16". Power requirements: 110V 60Hz.
| CD-45II Rotator Specifications |
| Wind Load Capacity (inside tower) |
8.5 square feet |
| Wind Load Capacity (with mast adapter) |
5.0 square feet |
| Turning Power |
600 pounds |
| Brake Power |
800 pounds |
| Brake Construction |
Disc Brake |
| Bearing Assembly |
Dual race/48 ball bearings |
| Mounting Hardware |
Plate clamps/Steel U-Bolts |
| Control Cable Conductors |
8 |
| Shipping Weight |
22 pounds |
| Effective Moment (in tower) |
1200 ft/lbs. |
The effective moment, of
an antenna is defined as the turning radius times the mass (or weight) of the
antenna and is expressed in ft.-lb. |